Outdoor applications

In real life, situations very frequently occur when it is necessary to protect various applications from snow, ice and icing – most frequently eaves troughs, downpipes and gutters or outdoor surfaces (pavements, drives, stairs etc.). These requirements occur in private but also industrial or commercial applications. Thanks to the simplicity of the solution and basically zero maintenance requirements, electric heating cables have an exclusive position here – other heating systems simply aren’t used for anti-freeze protection.

Heating of thoroughfares
Heating of roof applications
Thermal insulation of outdoor applications

A heating cable with suitable regulation will remove snow and ice automatically
Heating of thoroughfares

It is possible to protect any area used for passage with the help of heating cables – pavements, paths, drive-up ramps, staircases etc. Special heating cables are used for these applications – robust structures with stranded resistance and wattages of 20-30 W/m. The heating can be provided by a heating circuit as well as a heating mat. For thoroughfares which are walked on, the heating element is placed in a sand bed or into a concrete slab, while in the case of stairs, terraces and similar areas the element is embedded into bonding cement. In thoroughfares used for driving, we unambiguously recommend that the heating element is placed into a concrete slab which will protect the heating cable from damage when the thoroughfare is used by a car.

For thoroughfares which aren’t used by vehicles (pavements), the heating cable can only be placed into a sand bedFor the heating of outdoor surfaces a wattage of 300 W/m2 is installed. Such a high output is necessary for the system to function correctly even at temperatures far below freezing point. Also, correct regulation is very important – see the chapter Regulation of ECOFLOOR heating systems – – as it will bring the heating system into operation as soon as there is a danger of ice formation. This means a regulation system which registers not only the temperature but also the presence of moisture in the area monitored. If the system is controlled manually by the user and is brought into operation at a time when the surface concerned has already been covered with a layer of snow, this snow can take more than 12 hours to melt (depending on the height of the layer of snow). It is necessary to realize that the heating cable is placed in the ground, which has a great ability to absorb heat, and also that a large amount of energy is needed for the transformation of snow into water – so called latent heat. The installation of supplementary thermal insulation into the base composition is inefficient with a few exceptions; see the chapter Thermal insulation of outdoor applications. You can find the recommended floor compositions here...

Back to introduction
Heating of roof applications

As at certain geographical latitudes ice accumulates in the gutters and downpipes of a large number of buildings in the winter period, anti-freeze protection systems which use heating cables are applications which are in demand. Ice formation is caused by two influences:

  • after the exposure of a roof to the sun, the snow on it starts melting and the water which is flowing away accumulates in the gutters, where it gradually freezes
  • if loft rooms aren’t insulated perfectly, the escaping heat warms the roof structure – again, the snow melts on the roof and the water gradually freezes in the gutters

When the water outlet freezes completely, an ice layer starts to accumulate in the gutters and subsequently the water flowing over the edge of the gutters starts to form icicles. This can often create such a weight that the gutters will become irreversibly deformed. The trapped water can also get under the roof covering or leak onto the façade, where it will freeze and can cause great damage.

Icicles can be not only a romantic but mainly a dangerous roof decoration

An ideal protective measure is to provide the heating of eaves troughs and the heating of downpipes with the help of electric heating cables. Because of the price, mainly resistance heating cables are used, but it is also possible to use self-regulating cables. The shortest length of resistance heating cable is approximately 8m, and therefore if a shorter cable is needed, self-regulating heating cables may also be more suitable. Be careful, even self-regulating cables need to be controlled by regulation - see Regulation of ECOFLOOR heating systems. For typical eaves troughs and downpipes (up to a diameter of 150 mm), a heating wattage of 30-40 W/m is installed; at higher altitudes approaching 1000 m above sea level 60 W/m and more is used (after the assessment of local conditions). It is more advantageous to use a cable with a lower wattage and install it into the eaves trough or downpipe twice or even three times (a larger surface is thus covered) rather than use a higher output cable and install only one core. Plastic grips or steel cables with grips are used for the attachment of the cable in eaves troughs and downpipes.

Trough grip for a trough with a diameter of 100mm This grip for troughs with a diameter of 150mm is also suitable for self-regulating cables
The downpipe grip ensures that the cables in the downpipe don’t touch one another The plastic chain is used for the attachment of downpipe grips and for the hanging of the heating cable into the downpipe
SYFOK-B – steel cables are suitable particularly for downpipes which are more than 10m long SYFOK-P – has plastic grips which are suitable also for self-regulating cables
Spacer grips are suitable for cables freely laid in roof troughs – they prevent the movement and mutual contact of cables C type roof grips can be used as spacers, but they can also be used for the attachment of the heating cable to the sheet metal panelling  or into roof valleys by attaching them with 3M acrylic tape

It is also possible to protect roofs – roof valleys, edges of roofs etc. Here, the cable is usually installed in a so-called "saw-tooth configuration" with such a spacing that the surface wattage is ca. 200 W/m², and at least 250 W/m² at altitudes approaching 1000 m.

The cable is attached to the eaves trough using grips, usually as two conductors so that a larger surface can be covered. The cable can also be used for the protection of roof edges. In valleys the heating cable can be attached with the help of a steel wire (SYFOK)

The attachment of the cable on roofs is relatively problematic. Generally, it isn’t possible to make openings, solder or weld the coverings as doing this might damage the insulation boards under the covering. This problem is thus solved individually for each application – e.g. with the help of steel wires.

An interesting alternative is the attachment of the fixation elements (C type roof grips, plastic rails) using a double-sided adhesive tape from 3M. It is an acrylic foam tape of the 4611F type (width 19mm, 3 m reel):

  • It is first necessary to remove dirt and grease from metal elements (the sheet metal panelling of the roofs, troughs, valleys, C type roof grips) using industrial spirit or Acetone thinner (benzene isn’t suitable as it leaves particles on the metal parts which reduce the adhesive properties of acrylic tape), plastic elements (attachment rails, plastic troughs) also need to be coated with one layer of PRIMER self-etching adhesive at the places where the acrylic tape is attached.

As in the case with the heating of open spaces, a suitable regulation system which not only monitors the temperature but also the presence of humidity is extremely important for roof applications. If the heating cable is controlled manually by the user and is brought into operation at a time when a thick layer of ice is already present, the cable will melt a cavity (tunnel) in the ice and thus create an air shell which behaves in the same way as thermal insulation. Even though the cable is in operation, the ice doesn’t melt and the application is basically non-functional.

Back to introduction
Thermal insulation of outdoor applications

Users often enquire as to whether the efficiency of outdoor applications – the heating of thoroughfares – could be increased by the placement of suitable thermal insulation into the composition of their structure. Unfortunately, while in winter this insulation could speed up the warming of the upper layer and thus the melting of snow, in the transitional period it would insulate the heat accumulated in the earth and thus cause ice formation also in the spring and in the autumn when the ground isn’t generally frozen. Thermal insulation has its value only in applications in which the heated surface is exposed to ambient conditions from all sides. For example, in the case of an outdoor staircase where the stair carriage is above the ground, it is possible to carry out thermal insulation of the steps from the bottom side so that undesired leakage of warmth via that side is avoided.